| United States-English |
|
|
|
![]() |
Jazz home > Software > Beta Test patches > C.65.00 > MPENX16Bpatch details: MPENX16B |
|
Patch Description
MPEMXT3 UPDATE and INSTALL rework for 7.0 and 6.5
SR Number:
1000-764548
This patch is dependent upon: None
General Release Text
Known Conflicts
===============
Not applicable
Patch-to-Patch Dependencies
===========================
Not applicable
External Symptoms, Cause, Fix Description
=========================================
UPDATE or INSTALL from CSLT created during installation of patch MPEMXT3
fails with "BOOO DEAD" message on MPE/iX 7.0 or 6.5 (MPEMXT3 "B" for 7.5 does
not have this problem). Alternatively, the MPEMXT3 patch may be successfully
STAGEd with PATCH/iX, but UPDATE or INSTALL using tapes created from that STAG
will fail with "B000 DEAD".
Problem was due to a patch process error where modules from another patch
were incorrectly included when building the UPDATE and INSTALL PMEs. START,
DISCUTIL, SAT, STAGE and DUMP were all built correctly.
There are no defects with the enhancements made in the original MPEMXT3.
Therefore MPENX16 for 6.5 and 7.0 is MPEMXT3 rebuilt with new process checks
to ensure that all PMEs were correctly built.
Customer Environment Changes
============================
Not applicable
Hardware Dependencies
=====================
Not applicable
Software Product/Application Dependencies
=========================================
Not applicable
Product Version Information
===========================
See filename information for specific version changes for each module.
Dump Analysis
=============
Not applicable
OS Release VUF: C.65.00
Supersedes:
(0) MPEMXT3 C
(1) MPEMXU5 A (Current General Release patch)
(2) MPELXL0 A
(2) MPEMXT5 A
(3) MPEMXQ6 A
(4) MPEMXM0 C
(5) MPEMXN8 A
(6) MPEMXE1 C
(7) MPEMXG1 A
(8) MPEMXA1 A
(9) MPEMX92 A
(10) MPELX93 B
(10) MPEMX77 A
(11) MPEMX75 A
(12) MPEMX41 A
(13) MPEMX36 C
(14) MPEMX25 C
(15) MPELXR8 A
(16) MPELXN9 A
(17) MPELXM2 A
(18) MPELXJ2 A
(19) MPELXE3 B
(20) MPELXC5 B
(21) MPELX84 C
(22) MPEKXD2 B
(22) MPEKXD1 A
(23) MPELX72 C
Criticality:
(1) The system could experience a System failure without the patch.
Update Required: Yes